BIOBUZZ StarterBot V4: how the robot works
Team 20789 Paranoid Androids on Steroids. Dimensions come from the Fusion V4 model. Dashed paths are assumed and still need the bench test.
Validation so far
| Check | Result |
|---|---|
| Carriage swing, POLLEN to NECTAR pose | Measured in model: wheel group moves 14 mm back and 15 mm up, angle unchanged; 0 clashes at 5 poses. |
| Carriage strength | Fusion Static Stress, 60 N: 4.48 MPa, safety factor 61 (bonded contacts, so it understates hole-edge stress). |
| Shot speed range | Calculated with air drag, aimed at the real opening (centre 1.51 m): 7.0 m/s at 2.2 m to 8.0 m/s at 4 m at a fixed 50 degree ramp (the same for POLLEN and NECTAR). Wheel rpm for that speed is an estimate (about 2,800 to 3,200 rpm if ball speed is half the wheel surface speed); droop, squeeze and ball weight change it, so calibrate per ball on the bench. Stock motor limit is 6,000 rpm. |
| Shots from under 2 m | Rising entry: at a fixed 50 degrees the ball is still rising at the opening below about 2.2 m (7.8 m/s needed at 1.5 m). The opening is tilted 30 degrees, so a rising entry risks bounce-out. Straight-on from the field edge is about 1.5 m, so shoot from corners or add a steeper ramp. |
| Heading tolerance at the HIVE | Calculated: plus or minus 6 degrees at 2 m straight on, down to 2 degrees at 4 m and 45 degrees off axis. Robot rotation must hold under 2 degrees. |
| Camera sees the tags | Marginal beyond about 2 m: the manual puts each tag cluster on the bottom of the CELL, facing down (sec 9.9, 8.25 cm tags), so a camera 0.4 m high sees it at a grazing angle. At 720p that is under 2 pixels per tag module beyond 2 m; 1080p reaches about 2 to 4 pixels out to 2 m. Use Pinpoint odometry for range and bearing, and the camera as a close-range correction. |
| Windmill restored | Placed at stock position, no clash with the frame. Vane pockets for NECTAR (91 mm) not checked. |
| Windmill height | Does not touch the ball in the model: the deck is at z -14, so POLLEN tops out at z 57 and NECTAR at 77, while the restored vanes sit at z 82 to 99. Either the stock mount is lower than the V1 CAD or the vanes work on a ball sitting higher. Needs a look at the real robot. |
| Floor to deck path | Unproven. How a ball climbs the 42 mm lip is not documented. Bench test first. |
| Hold position in the model | Model conflict: the V3 hold ball overlaps the feeder roller by 4.6 cm3. The roller feeder duplicates the windmill. Reconcile on the real robot. |
| Shot reaction on the carriage | Computed, unmeasured: peak push 17 to 44 N (POLLEN) and 27 to 73 N (NECTAR). NECTAR end is carried by the hard stop. POLLEN end needs up to 37 N from the servo against 47 to 55 N available, so margin is thin; bench test 17 decides whether a latch is needed. |